WARNING:
If the information in these instructions are not followed ex-
actly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your build-
ing.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
908-785d
MODELS: U31-NG2 Natural Gas U31-LP2 Propane
03/05/08
U31 Gas Insert
Owners &
Installation Manual
www.regency-fi re.com
www.hampton-fi re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.excalibur-fi re.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - U31 Gas Insert

WARNING: If the information in these instructions are not followed ex-actly, a fi re or explosion may result causing property damage, personal injury

Strany 2 - FIREPLACE INSERT

10FPI U31-2 Gas Fireplace InsertDiagram 13) After fi ve minutes, test that there is a “pull” on the fl ue by placing a smoke match, cigarette or simil

Strany 3 - TABLE OF CONTENTS

11FPI U31-2 Gas Fireplace InsertLOG SET INSTALLATIONINSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken

Strany 4 - SAFETY LABEL

12FPI U31-2 Gas Fireplace InsertLogs D)02-46 and E)02-47 in position.6) Place the Left Top Log D)02-46 on the pin on Log C)02-56 and on top of the

Strany 5 - REQUIREMENTS

13FPI U31-2 Gas Fireplace Insert10) Place the embers and Rockwool on the exposed front burner tray.12) Test fi re to ensure proper light off (make sur

Strany 6

14FPI U31-2 Gas Fireplace InsertDiagram 4Diagram 5Rear View: Trim AssemblyDiagram 2Diagram 3Rear View: Faceplate AssemblyDiagram 1FACEPLATE & TRIM

Strany 7

15FPI U31-2 Gas Fireplace InsertBAY FRONT INSTALLATION1) Place the bay door onto the 2 pins on the top of the unit.2) Install bottom louver by slidi

Strany 8

16FPI U31-2 Gas Fireplace InsertINSTALLATION WIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors ca

Strany 9

17FPI U31-2 Gas Fireplace InsertFULL SCREEN FRONTINSTALLATION 1) Hold the full screen door up against the unit in order to make the following wire co

Strany 10 - INSTALLATION

18FPI U31-2 Gas Fireplace InsertINSTALLATION 5) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws.4) Install Spri

Strany 11

19FPI U31-2 Gas Fireplace InsertHAMPTON CASTFACEPLATE INSTALLATION1) Lay the faceplate panels fl at, face down on something soft so they don't sc

Strany 12

2FPI U31-2 Gas Fireplace InsertFPI GAS FIREPLACE INSERTNote: Oversize faceplate is 44" x 28" (1118 mm x 711mm)TO THE NEW OWNERCongratulatio

Strany 13

20FPI U31-2 Gas Fireplace Insert11) Mount the cast faceplate panels onto the insert body, sliding the side fi ller brackets into the space between th

Strany 14

21FPI U31-2 Gas Fireplace Insert1) Align the left side Faceplate Trim Bracket with the Firebox Flange and secure using 2 screws as shown in diagram 1

Strany 15

22FPI U31-2 Gas Fireplace Insert5) Place the bottom hooks of the Surround into the bottom slots of the Faceplate. Slightly pull up the Surround and p

Strany 16

23FPI U31-2 Gas Fireplace InsertOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list

Strany 17

24FPI U31-2 Gas Fireplace InsertCOPY OF LIGHTING INSTRUCTION PLATEOPERATING INSTRUCTIONSSHUTDOWN PROCEDURE1) Use the rocker switch to turn off the ma

Strany 18

25FPI U31-2 Gas Fireplace InsertTop View of pilot fl ameCorrect fl ame pattern has two strong blue fl ames: 1 fl owing around the thermopile and 1 reach

Strany 19

26FPI U31-2 Gas Fireplace InsertFAN MAINTENANCECAUTION: Label all wires prior to disconnection when servicing controls. Wiring error can cause imprope

Strany 20

27FPI U31-2 Gas Fireplace InsertPARTS LIST1) 400-011 Fan Opening Cover 400-515/P Fan Assembly (120 V)2) 910-331/P Fan Motor (120 V)5) 910-750 Power

Strany 21

28FPI U31-2 Gas Fireplace InsertPARTS LIST 402-560/P Valve Assembly - NG 402-562/P Valve Assembly - LP52) 910-028 Robertshaw Valve -Nat. Gas 91

Strany 22

29FPI U31-2 Gas Fireplace InsertPARTS LISTBay Door 400-988 Bay Door c/w Black Trims102) * Glass Retainer Side 103) * Glass Retainer Front 106) 940

Strany 23 - OPERATING INSTRUCTIONS

3FPI U31-2 Gas Fireplace InsertTABLE OF CONTENTSFPI GAS FIREPLACE INSERTOPERATING INSTRUCTIONSOperating Instructions ...

Strany 24

30FPI U31-2 Gas Fireplace InsertPARTS LIST 402-919 Complete Faceplate (Set) with Black Trim - Oversize41) * Faceplate Side Right - Oversize42) *

Strany 25 - MAINTENANCE

31FPI U31-2 Gas Fireplace InsertPARTS LIST

Strany 26

32FPI U31-2 Gas Fireplace Insert 402-971** Cast Faceplates (Set) 187) 910-246 Burner On/Off Switch188) 910-330 Fan Speed Control (120 V)189) 904-733

Strany 27 - PARTS LIST

33FPI U31-2 Gas Fireplace InsertNOTES_________________________________________________________________________________________________________________

Strany 28

34FPI U31-2 Gas Fireplace InsertNOTES_________________________________________________________________________________________________________________

Strany 29

35FPI U31-2 Gas Fireplace InsertWARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Qua

Strany 30

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Strany 31

4FPI U31-2 Gas Fireplace InsertSAFETY LABELThis is a copy of the labels that accompany each U31-2 Gas Insert. We have printed a copy of the contents h

Strany 32

5FPI U31-2 Gas Fireplace InsertREQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requirement

Strany 33

6FPI U31-2 Gas Fireplace InsertINSTALLATIONIMPORTANT: SAVE THESE INSTRUCTIONSThe FPI Gas Insert must be installed in ac-cordance with these instruct

Strany 34

7FPI U31-2 Gas Fireplace InsertINSTALLATION NOTE: Mantel clearances for Installation into a Zero Clearance Kit are different. Please refer to the Zero

Strany 35 - WARRANTY

8FPI U31-2 Gas Fireplace InsertTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!Conversion Kit from Nat

Strany 36

9FPI U31-2 Gas Fireplace InsertINSTALLATION TEST FOR FLUE SPILLAGEA " spillage" test must be made before the installed unit is left with the